You are here: Home - UPS On-line 3/3 phase - ORVALDI V10-20KRT
series: UPS On-line 3/3 phase
ORVALDI V10-20KRT 3-3/3-1
Powerful and flexible, the ORVALDI V10-20KRT UPS can be installed in TOWER or RACK setups, ensuring top-tier protection and power quality. It is ideal for safeguarding operations from unexpected outages in data centers, laboratories, and critical infrastructure
PRODUCT FEATURES:
- Critical infrastructure support and protection against power outages.
- Full microprocessor control.
- Ability for remote monitoring of device operation.
- Zero switching time.
- Clean sine wave
- Cold start function.
- Easy to read LCD display.
- Ability to operate in parallel with another device.
- User-friendly device.
- EPO connector.
- EMBS connector.
LIST OF APPLICATIONS:
- Telecommunication devices.
- Laboratories and Scientific research.
- Servers and data centers.
- Industrial devices.
- Critical Infrastructure.
DOWNLOAD:
"HIGH QUALITY" OPTION:
ORVALDI will, in accordance with the terms and conditions of insurance, replace, repair or compensate ORVALDI products and/or connected devices in the event of damage as a result of an electrical surge. The maximum total amount compensated is 5000Euro (five thousand Euros).
Topology
The UPS operates with VFI on-line technology, ensuring the highest power quality for connected devices. A key feature of this solution is its seamless transition between operating modes, ensuring continuity and optimal protection for all critical systems.
Display
The device features a user-friendly display with pictograms that clearly indicate the UPS’s status and operation. Its compatibility with both RACK and TOWER installations allows for flexible adaptation to various space configurations.
- Mountable in a RACK cabinet or as a TOWER-type power supply
- Configurable power supply: 3-phase to 3-phase or 3-phase to single-phase
- Power Factor: Output power factor of 1.0
- Touchscreen: 3.5-inch intuitive interface for easy operation
- EPO (Emergency Power Off) switch
- Parallel operation: Supports up to three units for increased power
- Super charger: 12A charger
- Compatible with generators
- Bypass mode: Maintenance Bypass (MBS - maintenance bypass)
- Communication: Standard: USB, optional: SNMP, AS400, WiFi module
- UPS dimensions: 438 x 133 x 680 mm [rack 3U] (W x H x D)
EMBS
The EMBS connector allows for intelligent connection of an external service bypass module. This enables safe bypassing of the UPS during servicing or maintenance, while maintaining continuous power supply to connected devices. The system is designed to automatically detect the opening of the external bypass cover and switch to the internal bypass mode, preventing accidental switching and potential damage to both the UPS and the connected equipment.
Maintenance Bypass
The EMBS connector enables intelligent connection to an external service bypass module, allowing safe UPS bypass during maintenance while ensuring power continuity for connected devices.
Here is the translation of the list into English: 1 - COLD START switch |
Communication
Network Control and Monitoring Features
- Enables control and monitoring of multiple UPS units via LAN and INTERNET.
- User-friendly power analysis chart: event statistics, historical data graph export.
- Real-time dynamic UPS data charts (voltage, frequency, load level, battery level).
- Secure OS shutdown and data loss protection in the event of a power failure.
- Warning notifications via audible alarm, broadcast program, mobile messenger, and email.
- Scheduled UPS on/off, battery test, programmable outlet control, and audible alarm control.
- Password protection and remote access management.
- Supports VMware ESX and ESXi.
- Multilingual support: English, German, French, Spanish, Italian, Portuguese, Polish, Czech, Russian, Ukrainian, Turkish, Chinese.
The UPS is equipped with USB and RS232 ports, as well as an SNMP card slot, allowing for easy management and remote monitoring from a computer, enhancing the safety of connected devices.
ViewPower |
ViewPower Pro |
SNMP Web Manager |
Smart management software to montior and control multiple UPS via LAN and Internet. | Advanced management software to monitor and control multiple UPSs via LAN, Internet, and SNMP card. | SNMP Web Manager is a SNMP web card manager software. Users can search and operate all SNMP devices in the LAN via this interface. Then, user can double click device to open web server monitoring page. |
Installation Flexibility
3-phase to 3-phase or 3-phase to single-phase installation
3-phase to 3-phase or 3-phase to single-phase installation
The UPS design allows flexible switching between three-phase power and single-phase or three-phase loads, providing maximum versatility. This makes it easy to adapt the power supply to a variety of devices, optimizing system efficiency and reliability. It’s an ideal solution for dynamic IT environments that require flexibility and uninterrupted operation.
Redundancy and Scalability
The parallel connection function allows for power capacity expansion by adding more UPS units, creating a redundant system that ensures continuous operation even if one device fails. This feature enhances flexibility and reliability in the power backup system.
Additional Features
The device includes an EPO (Emergency Power Off) connector, ensuring the safety of connected infrastructure in emergencies. This critical feature enables immediate power shutdown, reducing risks to life and equipment during unforeseen events.
Efficiency Modes
Includes an ECO mode that optimizes power usage without compromising protection, making it energy-efficient.
TECHNICAL DATA:
Model | ORVALDI V10KRT | ORVALDI V15KRT | ORVALDI V20KL | |
Apparent Power/Active Power | 10kVA /10kW | 15kA / 15kW | 20kVA / 20kW | |
Input | ||||
Voltage Range | Lower Voltage Threshold for Power Loss | 110 VAC(Ph-N) ± 3% at 50% load | ||
176 VAC(Ph-N) ± 3% at 100% load | ||||
Lower Voltage Recovery Threshold | Lower Voltage Threshold for Power Loss + 10V | |||
Upper Voltage Threshold for Power Loss | 300 VAC(L-N) ± 3% at 50% load | |||
276 VAC(L-N) ± 3% at 100% load | ||||
Upper Voltage Recovery Threshold | Upper Voltage Threshold for Power Loss - 10V | |||
Frequency Range | 46Hz~54Hz @50Hz system | |||
56Hz~64Hz @60Hz system | ||||
Phases | 3 phases with neutral | |||
Power Factor | ≥ 0.99 at 100% load | |||
Output | ||||
Output Voltage | 3x 360/380/400/415VAC (Ph-Ph) | |||
208/220/230/240VAC (Ph-N) | ||||
Voltage Regulation (AC mode) | ± 1% | |||
Frequency Range (Synchronized Mode) | 46Hz~54Hz @50Hz system | |||
56Hz~64Hz @60Hz system | ||||
Frequency (Battery Mode) | 50Hz ± 0.1Hz or 60Hz ± 0.1Hz | |||
Peak Current Factor | 3:1 max | |||
Harmonic Distortion | ≤ 2% at 100% linear load; ≤ 5% at 100% non-linear load | |||
Overload | AC Operation Mode | 100%~110%: 60min; 110%~125%: 10min; 125%~150%: 1min; >150%: 400ms | ||
Battery Operation Mode | 100%~110%: 60min; 110%~125%: 10min; 125%~150%: 1min; >150%: 400ms | |||
Switching Time | Inverter ⇿ Bypass | 0 ms (when phase locks, <4 ms from inverter to bypass) | ||
On-line ↔ Battery operation | 0 ms | |||
Inverter ⇿ ECO | <10 ms | |||
Efficiency | ||||
AC Mode | 95.5% | |||
Battery Mode | 94.5% | |||
Batteries | ||||
Quanity | 20 | 32~40(Ajustable) | ||
Charging Current | 1.0~12.0A ±10% (adjustable) | |||
Charging Voltage | 136.5VDC+/-1% | +/- 13.65VDC * N ± 1% (N = 16~20) | ||
Physical | ||||
Dimensions D x W x H (in mm) | 680x438x133 (3U) | |||
Net Weight (kg) | 26 | 28 | ||
Environment | ||||
Operating Temperature | 0 ~ 40°C (Battery lifespan decreases above 25°C) | |||
Humidity | <95% non-condensing | |||
Operating Altitude | <1000 m | |||
Noise Level | Less than 62dB @ 1m | Less than 65dB @ 1m | ||
Management | ||||
Smart RS232 or USB | Software for Windows 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC | |||
Optional SNMP | Management via SNMP manager or web browser |